A significant component of a split system, of course, is a refrigeration compressor. It is thanks to this component of the technological scheme of a household or other machine that they get the cooling effect, as well as the effect of air humidification.
If it happens that the compressor unit for some reason does not work, the split system, in fact, turns into an ordinary windmill. The desired effect from such a "mill" can no longer be obtained, and the owner of the system just right to think about the repair.
However, in order to repair, you need to know how to check the air conditioning compressor of the split system for a malfunction. We will deal with this issue in our article. We also consider the device module, common types of malfunctions and provide recommendations for repair.
Compressor module device
To begin with, briefly about the refrigeration compressor, as a module that is part of the air conditioner. This equipment relates to electromechanical devices, the distinguishing feature of which is the complete sealing of the internal contents.
That is, in case of any mechanical (electrical) malfunctions, you can not just take, disassemble such a device, like many others, to get to the faulty node. Everything is much more complicated here. In some cases, you even have to dismantle the split system.
That is why in case of serious malfunctions, the refrigeration compressor of a split system is easier to replace with a new one, rather than trying to repair.
Examples of compressor units from those diverse options that are used on household split systems. The classical form, as a rule, is cylindrical, but in terms of overall dimensions the variety of designs is great
If we consider the machine in a generalized way, theoretically, the mechanical part of the refrigeration compressor resembles a traditional air compressor.
The machine also contains a connecting rod and piston system, although often of a rotary type, bearing units, and a valve system. But all this is enclosed in a hermetically sealed metal case.
External and internal structure of the compressor: 1 - bearing balancing assembly; 2 - channels for oil; 3 - drive motor; 4 - spiral design; 5 - discharge pipe; 6 - valve system; 7 - coupling; 8 - oil pan; 9 - supporting base
There, inside the case, an electric drive is mounted. The drive system is made in such a way that a winding of wires that does not have air cooling receives cooling from the working refrigerant - freon
This quite effective internal cooling method ensures the durability of compressor motors. In practice, motor failures are noted, but rarely enough.
Compressor Symptoms
It should be understandable when the split system is not able to provide the specified temperature, this factor may indicate that the compressor is not working.
In addition, the operation of the compressor unit of the air conditioner is clearly determined by the characteristic noise effect that the refrigeration unit creates. The noise of the equipment is not to say that it is strong, but during the operation of the unit it is audible with confidence.
If a decision is made to repair the internal defects of the refrigeration compressor, you have to dismantle the device from the system, having previously released the circuit from the refrigerant
By the way, again, based on the noise level, some types of defects of the compressor machine are determined. So, if during operation an increased clicking sound or a rattle sound is noted, most likely, it is possible to state the wear or damage of the valves.
With such a malfunction, the compressor performance drops sharply, the casing of the device is very hot. As a result, the internal thermal relay is activated, the operation of the machine is blocked.
Often there is a situation when, almost immediately after starting the compressor, its operation is terminated. However, at the same time, the device itself is practically intact and operational.
The cause of the defect in such a situation is usually the lack or overflow of the circuit with refrigerant. An emergency stop is provided by a thermal relay, which, by the way, can also fail.
One of the designs of the thermal relay, of those that are used to protect the compressor of the split system from heating above the permissible temperature. Meanwhile, this device may also be faulty.
Finally, the owner of the split system may encounter a working moment - when the compressor unit simply does not start. At the same time, the air conditioner is quite functional in terms of all other functions.
The compressor does not give rise to a statement of defects - it looks outwardly unharmed. The traditional reason for this option, as a rule, is the inoperability of the starting capacitor with a capacity of 10 μF or more.
The capacitors responsible for the moment the split-system compressor was started look like this. Depending on the capacity of the compressor unit, the working capacity of such parts varies
The most severe and practically unrecoverable defect of a split system compressor is the inter-turn short circuit in the stator windings of the drive motor. True, we must pay tribute - in modern designs of hermetic compressors, such a malfunction rarely occurs.
Defect check
Consider the possible actions of a mechanic or user of a split system, taking into account all the malfunctions that were noted above.
But first, take into account the following points:
- Such equipment is maintained by specialists. Here we talked about self-cleaning the split system.
- The system is charged with chemically harmful substances.
- The device operates on a high potential network.
- Requires knowledge of electricians, electronics, mechanics.
- There is a danger of harm to health.
A calm, reliable and qualified way to check the system is, of course, an appeal to professional masters.
Nevertheless, the possibility of using personal skills at their own risk is not ruled out. For the second option, we consider methods for checking equipment for malfunction.
Problem # 1 - High Mechanical Noise
So, if the machine emits increased noise, not typical for normal operation, we can state with high confidence the destruction of internal components.
It can be bearing units, valve group parts and others. In such cases, the only option is to replace the unit.
Attempt to repair unit that has received internal damage. To access the internal content had to cut the case with a cutting wheel. Meanwhile, after repair, you will have to tightly weld the case
Increased noise can also be noted due to excessive mass of refrigerant charged into the system. However, in this case, the nature of the noise is clearly different from the mechanical one, and after a short operation, the compressor is usually turned off by the automation system according to the high pressure parameter.
The check for these two options is accompanied by the following actions:
- Connect the gauge station to the discharge side.
- Close the system tap on the contour line.
- Monitor pressure readings.
With faulty valves, the noise level usually increases, but the pressure does not actually change or changes slightly. If the bearings are faulty, an increase in noise will be accompanied by an increase in pressure.
Using a gauge station to check the amount of refrigerant in the circuit pumped by the compressor. Often, due to a shortage or surplus of the working substance, the operation of the unit is disturbed
Excessive refrigerant in the circuit will also show an increase in pressure with increasing noise and subsequent shutdown of the compressor by the automation system (pressure switch). We wrote more about the device of this node, its principle of operation, connection and adjustment in the next publication.
Problem # 2 - overflow or lack of freon
A “malfunction” of this kind is determined, again using a gauge station. It is necessary to disconnect the split system from the network, wait a bit, then connect the gauge station and start the air conditioner. Observe the readings on the instruments.
The operating pressure for a household split system of a specific configuration can always be determined by the technical tag (plate) fixed on the external module case. There, on the plate, the boundary pressure parameters of the contour sections of the discharge and suction are indicated.
A plate with boundary parameters, where the boundary values of the discharge and suction pressures are indicated. For troubleshooting purposes, it is recommended that you refer to this label.
If the table limits are exceeded, this indicates a clear overflow of the system with refrigerant. However, the table only gives the upper pressure values.
Therefore, the lack of refrigerant is already determined in a slightly different way. The average rate of suction pressure for household split systems is approximately 4-6 Bar (ATI), depending on configuration.
When the pressure indicator of the suction part of the circuit at the gauge station is significantly less than the specified range of 4-6 Bar, this factor indicates a lack of filling.
This condition also affects the operation of the compressor when abnormal noise and periodic operation of protective systems are noted.
Problem # 3 - no start of refrigeration compressor
A common defect in the split systems associated with the compressor is the complete absence of the start of the refrigeration compressor. At the same time, the system successfully enters the cooling mode, all automation devices work normally. Another question is the condenser fan.
The split system fan is stopped immediately when the air conditioner is turned on - this is a clear sign of failure of the starting capacitor, through which the compressor unit is supplied with current
In this condition, the split system of the condenser fan shows a somewhat unusual operation. When the air conditioner starts up, the fan impeller starts to rotate, but almost immediately the rotation stops.
The indoor unit of the air conditioner continues to function when the compressor of the outdoor unit is idle.
This defect, as a rule, manifests itself on systems that have successfully worked for several years (more than 5). And the reason for this behavior of the system is the starting capacitor included in the power circuit of the compressor motor.
It’s easy to diagnose a capacitor malfunction. How to do this is a little lower.
Problem # 4 - inter-turn stator winding
How to determine such a malfunction is far from a controversial issue. For example, when there is a short circuit of 2-3 turns in a short section, it is practically impossible to identify a defect without using a specific tool.
Damaged compressor winding split system. In this case, there is a break in the individual conductors. This type of repair is possible only in workshop conditions and even then not always with positive success.
Other variations, when sufficiently remote sections are closed to each other, in principle, can be determined by a simple measurement of the resistance of the working windings of the motor stator.
Usually the winding where there is a "short", gives less resistance to other windings. However, an accurate motor circuit will be required.
Equipment Repair Tips
Split system compressor internal defects are repaired exclusively by professional workshops. At home, the efforts of the owner of such complexity repair seems to be irrational, with an extremely small percentage of successful execution.
If the normal operation of the compressor is disturbed due to surplus or lack of refrigerant, the repair task can be completely resolved on its own.
In the first case (excess freon), it is enough to simply remove part of the gas from the system. In the second case, it is necessary on the contrary - to fill the system with an additional volume of gas.
With an interturn circuit, repairing at home is seen as a futile exercise. Such a malfunction is difficult to repair even in a professional workshop.
When the starting capacitor is the cause of compressor failure, open the top cover of the outdoor system unit by first disconnecting the machine from the power supply.
Remove the capacitor and check with a tester in the resistance measurement mode (mOhm), alternately touching the test terminals with the probes. A non-working capacitor will not show a discharge effect. This is a reason to replace.
This video was shot by specialists and can be useful for those who are eager to repair a split system compressor that has serious damage.
The operation of modern split systems shows a very long-term operation without the need for repairs. Especially when it comes to serious defects, such as inter-turn short circuit or mechanical wear.
Simple malfunctions can be repaired quite simply, and in the case of complex defects, a reasonable solution is to replace the split system with a new one. Serious repairs will force you to spend as much money as the purchase of a new split system requires.
Would you like to share compressor diagnostic methods that we did not talk about in this article? Write your comments, additions and recommendations in the block below.
If you are trying to figure out the cause of the breakdown of your split system yourself and find yourself in a difficult situation - do not hesitate to ask our experts and other visitors to the site for comments in the comments on this article.