Installing a pump for a stable supply of water to the house requires the connection of additional valves. A non-return valve for the pump is mounted in the water supply system or on the suction pipe lowered into the well, a small but useful device.
Do you want to equip the pumping system yourself with back-stop valves, but don’t know how to do it correctly and which valve is suitable for these purposes?
We will help to understand the issue - in this material we offer to get acquainted with the design, the principle of the check valve, the main varieties. And also we will provide step-by-step instructions for installing it.
Purpose and principle of operation of the valve
A non-return valve, like any device for a water supply system, is installed in order to protect the network from any changes in flow parameters. Simply put, so that water is supplied continuously, without stops and interruptions, in the right amount.
A narrower purpose of the valve is to organize the movement of water in one direction and an obstacle to its return movement.
Manufacturers of pumping stations equip the sets with a valve, and if this element of shutoff valves is not available, then insist on its mandatory purchase
The tasks that such a valve installs on the pump line:
- stabilizes the pressure and pressure of water when moving from a well or a well;
- organizes the supply of water in the right direction - from the source to the consumer;
- keeps the highway constantly filled;
- protects equipment from pressure surges, force majeure situations and unscheduled repairs.
The principle of operation depends on the type and design of the valve. Consider it as an example of a device designed for tapping into a pipe.
The simplest model for plumbing, made of brass and stainless spring steel. Connection method - coupling, thread - internal. Designed for temperatures up to +110 ˚С
The main structural elements of the check valve are two working parts: saddle and locking element. To return the locking element to its primary position, a spring is intended.
The principle of operation of the check valve is simple. When the fluid flows in the forward direction, from the source to the internal networks, the valve disc moves inside the housing, opening a gap for water. If the fluid moves in the opposite direction, the locking element is firmly pressed against the seat and completely covers the passage section.
The locking element has several options: cylindrical spool, cone, ball, plate. Accurate hit on a saddle during the return movement provide additional guides
Without back-stop valves, when the pump was turned off, the liquid, according to the laws of hydrodynamics, would go back to the well or well.
Types of back-locking devices
At the installation site, all check valves designed for pumping equipment are divided into two categories:
- for mounting on the suction pipe of a surface pump or through an adapter to a submersible pump;
- for installation on the pipeline.
The former prevents the reverse movement of water and ensures that the system is constantly filled, the latter regulate the pressure in the water supply.
We recommend installing both types of back-stop valves, as the functions of the devices differ.The valve on the suction hose additionally protects the pump from "dry running", prevents the occurrence of air congestion, that is, it is responsible for the health of the pump. Even if the equipment is initially equipped with the option of protection against "dry running", thanks to the non-return valve, you do not have to constantly fill the water.
Installing such a valve at the suction site is a must. But to stabilize the pressure in the system, a similar device is mounted in front of the pumping station or in front of the hydraulic tank, if it is located separately
Valves that are installed on the pipe in the house wiring prevent fluid from returning outward to the pump or well. They maintain the necessary pressure of water and regulate pressure. The main function of pipe models is the protection of pumping and plumbing equipment from sudden pressure surges and water shocks.
Check valves for borehole pump
Check valves installed on the suction line are called bottom valves. They are used in a set of pumping stations to prevent the discharge of water from the network back into the well and maintain the pressure at the desired level.
Models differ in design. Usually used spring, less often - butterfly valves. Whereas in spring, the main working elements are a spring and a disk that blocks the flow, in case of casement, there are 1-2 valves, opening under the pressure of the liquid.
The method of attaching the device to a pipe or hose is also different. More commonly used products with muffed mounting method, less often - with flanged.
A popular type of valve for submersible pumps is a spring device with a coupling method of attachment. Installation is made on the PND pipe using a threaded connection
So that the valve does not become clogged and the sediment from the bottom of the source does not move further into the pumping equipment, a fine mesh filter is installed under it.
Types of pipe check valves
Depending on the installation conditions and the features of the water supply system, valves are installed that differ in design, size, material and method of attachment. Some are designed for pipes of small diameter and domestic use, others for centralized water supply.
Consider the basic classification of check valves for water.
Classification # 1 - by type of locking element
The part of the valve inside the body that is responsible for overlapping the section is of various configurations.
The following types of devices are distinguished by a locking element:
- Liftingin which the shutter device moves up / down depending on the presence or absence of water pressure in the pipe. The spring is responsible for the dynamics, and the spool acts as a shutter.
- Swivelalso equipped with a spool - flap or "petal". When the pump is turned on, it leans back and frees up the path for the liquid; when turned off, it closes, blocking the cross section.
- Bivalveblocking the path to the water flow with two connecting leaves.
The movement of the locking element occurs in parallel, perpendicular to the axis or at an angle, so manufacturers recommend that some devices be installed only on horizontal pipes, others on vertical ones.
For domestic use, it is advisable to purchase spring valves, characterized by a simple design and ease of installation. If you decide to independently equip the pumping system with back-stop valves, we recommend this model.
Sample of a spring valve installed in the boiler piping and water hammer warning. A pumping station that pumps water from a well is connected to the system
The design of the spring valve consists of the following elements:
- brass body (steel, polymer), consisting of two parts - the base and the cover with a saddle;
- disk element with a rubber seal that abuts the saddle;
- stockperforming centering and holder functions;
- spring to return the locking element to its initial state.
Such valves as rotary valves are almost never used in domestic water supply, but they are often used for industrial pipelines, the diameter of which reaches 0.5 and even 1.5 m.
Classification # 2 - by type of mount
Insertion into the pipe is carried out in various ways, which are selected depending on the pipe material and installation conditions.
The most acceptable are four types of valves:
- flanged;
- interflange;
- coupling;
- welded.
In systems coupled with pumping stations, it is advisable to use a coupling type with a spring mechanism and simple installation. But in more "serious" networks, for example, for equipment for supplying water to an apartment building, all of the above types are successfully used.
Image Gallery
Photo from
Cast iron flanged industrial models
Disc Type Inter Flange Valves
Coupling devices for tapping into a home pipeline
Models for welding
If you decide to install a check valve in the home pumping network, you should stay on the coupling model. Devices can be purchased in specialized stores at a price of 40 to 600 rubles. Product size - 1ˮ, 1 / 2ˮ, 3 / 4ˮ.
Classification # 3 - by material of manufacture
The valve bodies are made of materials that reliably protect the internal mechanism, which are not deformed from the action of the external environment and fluid flowing through the pipes.
Check valve on the pipe happens:
- steel;
- cast iron;
- bronze;
- brass;
- plastic.
Products installed near centrifugal pumps in the heating system must be metal, since plastic is not suitable for hot water.
A sample of brass OK, universal in application. It is installed on both metal and plastic pipes. The product does not rust bends, does not change technical characteristics over time
Cast iron valves are characterized by high weight and roughness of the material. But they are not used for the equipment of autonomous home networks, but are installed only for industrial operation on large-diameter pipes.
Devices from plastic lightweight and inexpensive, their installation is very fast. But they can not be applied to serious water systems at home.
Polymer products are suitable for polypropylene pipes in networks with a small pressure of water - for example, for watering a garden or pumping water into a bath
Internal parts - a saddle, locks, a stock - of valves are made of polymers, stainless steel or aluminum. They are durable and corrosion resistant. The acting element, a spring, is made of special spring steelhaving an extended service life.
In valves installed on centralized highways and industrial facilities that can withstand heavy loads, plastic or rubber seals.
Recommendations for installing such a valve
Consider one of the options for installing a check valve - on the submersible pump "Aquarius". The device is connected directly to the pump. As soon as the unit stops working, the valve shuts off the water so that it does not drain back down. Due to this, the line is constantly filled with liquid.
The procedure for connecting the bottom check valve:
Image Gallery
Photo from
Step # 1 - Preparing the Check Valve
Step # 2 - attaching the adapter
If there is no arrow on the check valve indicating the movement of water, you can try to purge it. The valve is screwed to the pump on the side with which it is freely blown.
There are several rules regarding the location of the valve inside the well. If it is installed on the surface pump pipe, the distance to the bottom should be at least 0.5 m. The manufacturer indicates the exact parameters in the technical data sheet.Also observe the distance to the water surface - at least 0.3 m.
If the non-return valve is installed in a water supply system operating from a pump inside the house, then the main thing is to choose the right place. Usually two devices are installed - separately on the line of hot and cold water
We recommend that you observe the following procedure: install a ball valve at the inlet, then a strainer, followed by a meter, and only then a check valve.
Some metering devices are equipped with built-in valves, but they are not very reliable, so it is better to play it safe and install the device separately.
Recommendations for the selection and installation of a check valve for a submersible pump:
Details of the design and purpose:
About the nuances of installing the valve in the following video:
The need to install check valves is not worth discussing - this device is required for the stable operation of the water supply system. It is used with both submersible and surface pumps to extend equipment life and protect the system from accidents.
Have experience installing a check valve? Or want to ask advice from our experts or from more experienced users in this matter? Ask your questions, share your own opinion in the comments section below this article.